Pump Won't Prime

A pump that can't draw water up from the source (won't prime) has an air leak on the suction side, a failed foot valve, or the suction lift is too high.

Want an expert watching over your shoulder?

Chat with The Sprinkler Guy directly and get real-time help on your repair.

Chat — $29.99

Symptoms

  • You fill the pump with water but it won't draw from the well/pond
  • Air keeps coming into the pump volute
  • Pump runs dry and overheats

Diagnosis

Air is entering the suction line faster than the pump can purge it, preventing the pump from creating enough vacuum to draw water.

Step-by-Step Repair

  1. 1

    Turn off the pump. Fill the pump volute and suction pipe completely with water through the priming port.

  2. 2

    Start the pump. If it briefly pressurizes then loses prime, you have a suction-side air leak.

  3. 3

    Inspect every fitting, joint, and connection on the suction pipe from the pump back to the water source. Tighten all connections.

  4. 4

    Check the foot valve at the water source. A stuck-open foot valve lets water drain back. Replace if the flapper doesn't seal.

  5. 5

    Verify the suction lift (vertical distance from water level to pump) doesn't exceed 25 feet. Centrifugal pumps can't reliably lift more than this.

  6. 6

    Apply soapy water around suction-side fittings while the pump runs. Bubbles indicate an air leak at that joint.

Pro Tips

  • Thread sealant (pipe dope) works better than Teflon tape for suction-side threaded connections because it fills gaps more completely.

Prevention Tips

  • Install a check valve close to the pump to help maintain prime. Foot valves alone aren't always enough.